Model L-435 HVL Filter Holder
The new Ludlum L-435 HVL Filter Holder is designed to simplify the routine HVL measurement process. For years the method of attaching the HVL filters to the X-ray collimator involved using quantities of medical/surgical tape. While tape does the job, it also tends to destroy the thinner aluminum filters, particularly the high purity mammography filters.
The Model L-435 HVL Filter Holder eliminates the need to use tape to attach the HVL filters to the collimator housing.
The filter holder consists of a polycarbonate base 24.1 x 24.1 cm (9.5 x 9.5 in.). Permanently bonded to the center of the base plate is an acrylic pocket, open on one side and designed to hold a standard or high purity Al filter set. The polycarbonate material is easily cut with a standard utility knife or sheers to accommodate the two most common collimator track sizes in a given department. The base may also be attached with the hook-and-loop type fastener strips supplied for odd sized collimators. In either case, the filters themselves are protected from damage associated with the application and removal of heavy medical/surgical tape.
Request a quote Download Spec SheetRelated Products
Headphone Jack
This modification for survey meters adds a headphone jack to the instrument body so headphones can be used to monitor click-per-event audio and audio alarms. Headphones are helpful when the instrument is being used in areas with high ambient noise levels or in areas where the audio would be distracting to others, such as in a medical or office environment.
Shoulder Strap
This 1.8 m (6 ft) adjustable shoulder strap is a great way to keep your hands free while operating survey meters. The nylon strap with a wide rubber comfort pad can also be helpful for conveying some of the heavier instrument/detector combinations in the field.
Model 3-IS NORM Kit
- Ready-to-Go Kit in Rugged Case
- Intrinsically Safe Analog Survey Meter
- Measures Alpha, Beta, and Gamma Contamination
- Includes:
- Model 3-IS Intrinsically Safe Survey Meter
- Model 44-9 Alpha-Beta-Gamma Detector
- Model 44-2 High Energy Gamma Detector
- Check Source, Cable, Batteries, Transport & Storage Case
Model 14C-MERK
Medical Environment Response Kit
- Model 14C Survey Meter
- Model 44-2 Gamma Scintillator Detector
- Model 44-9 Alpha-Beta-Gamma GM Detector
- Model 25 Series Personal Radiation Monitor
- Check Source and Holder
- Rugged Case
Model 2241-3MERK
Medical Environment Response Kit
- Model 2241-3 Scaler-Ratemeter
- Model 44-2 Gamma Scintillator Detector
- Model 44-9 Alpha-Beta-Gamma GM Detector
- Model 44-142 Beta Scintillator Detector
- Model 25 Series Personal Radiation Monitor
- Check Source and Holder
- Rugged Case
Model 3001-MERK
Medical Environment Response Kit
- Model 3001 Survey Meter
- Model 44-2 Gamma Scintillator Detector
- Model 44-9 Alpha-Beta-Gamma GM Detector
- Model 44-142 Beta Scintillator Detector
- Model 25 Series Personal Radiation Monitor
- Check Source
- Rugged Case
Model 14C-RK
Emergency Response Kit
- Model 14C Survey Meter
- Model 44-2 Gamma Scintillator Detector
- Model 44-9 Alpha-Beta-Gamma GM Detector
- Check Source and Holder
- Rugged Case
Cables
Ludlum offers straight cables with either type C, BNC, SHV, MHV, or UHF connectors. Unless specified otherwise, Ludlum survey meters and detectors are shipped with “C” type connectors. When a meter and accompanying probe are ordered as a matched set, Ludlum automatically includes a 99 cm (39 in.) straight-type cable with “C” connectors at no additional charge. (Note: We no longer offer coiled cables.)
Model 3002/FM Series
Alpha-Beta Floor Monitor
- Alpha-Beta Scintillation Detectors
- Active Window Area: 400 or 1080 cm2 (62 or 167.4 in2)
- 22.4, 40.9, or 65.7 cm (8.8, 16.1, or 25.9 in.) Wide Detection Path
- Adjustable Detector Height
Model 42-38
WENDI-2 Wide Energy Neutron Detector
- Detector Type:
- 3He Tube
- Moderator: 22.9 cm (9 in.) dia.
- Sensitivity (241Am/Be): 450 cpm per mrem/hr
- Detection Range: Thermal to 5 GeV
Model 78-6
Stretch Scope Survey Meter
- Analog + Digital Meter
- Extends to 3.6 m (12 ft.)
- NaI(Tl) Scintillator Detector
- Range: 0.01 to 50 µSv/h (1 to 5000 µR/hr)
Model 79/2
Stretch Scope Survey Meter
- Digital Meter
- Extends to 4.5 m (14.75 ft.)
- Internal Energy-Compensated GM
- Range: 0.001 mSv/h to 0.04 Sv/h (0.1 mR/hr to 4 R/hr)
Model 79/1
Stretch Scope Survey Meter
- Digital Meter
- Extends to 4.5 m (14.75 ft.)
- CsI(Tl) Scintillator Detector
- Range: 0.01 µSv/h to 500 µSv/h (1 µR/hr to 50 mR/hr)
Model 79
Stretch Scope Survey Meter
- Digital Meter
- Extends to 4.5 m (14.75 ft.)
- Energy-Compensated GM Detector
- Range: 10 µSv/h to 10 Sv/h (1 mR/hr to 1000 R/hr)