- Home
- All Products
All Products
Stuart Hunt & Associates provides a full range of radiation safety products for regulatory compliance and custom solutions for business.
Model 2401-P
Dose Pancake GM Pocket-Size Survey Meter with Dose Filter
- Alpha-Beta-Gamma Survey
- 3-Range Analog Meter
- Internal Pancake GM Detector
- Sensitivity (137Cs): 3300 cpm per mR/hr
- Range: Meter Face Dependent
Model 2401-P Pancake GM Pocket-Size Survey Meter
The Model 2401-P instrument is a general purpose, pocket-size radiation detection meter designed around the venerable GM pancake detector. The detector is conveniently packaged inside the instrument with a protective screen window. This instrument is available with a variety of meter faces for measuring contamination and exposure rate in either R or Sv units (see list on the Meter Faces tab).
Model 2401-EWA
End-Window GM Pocket-Size Survey Meter with Alarm
- Alpha-Beta-Gamma Survey
- 3-Range Analog Meter
- Internal End-Window GM Detector
- Sensitivity (137Cs): 1050 cpm per mR/hr
- Range:
- 0 to 200 mR/hr
- 0 to 210,000 cpm
- Alarm
Model 2401-EW
End-Window GM Pocket-Size Survey Meter
- Alpha-Beta-Gamma Survey
- 3-Range Analog Meter
- Internal End-Window GM Detector
- Sensitivity (137Cs): 1050 cpm per mR/hr
- Range:
- 0 to 200 mR/hr
- 0 to 210,000 cpm
Model 2401-EC2A
Pocket-Size Survey Meter with Alarm
- Gamma Survey
- 3-Range Analog Meter
- Internal Energy-Compensated GM Detector
- Sensitivity (137Cs): 120 cpm per mR/hr
- Range: 0 to 200 µSv/h (0 to 2 R/hr)
- Alarm
Model 2401-ECA
Pocket-Size Survey Meter with Alarm
- Gamma Survey
- 3-Range Analog Meter
- Internal Energy-Compensated GM Detector
- Sensitivity (137Cs): 1050 cpm per mR/hr
- Range:
- 0 to 200 mR/hr
- 0 to 210,000 cpm
- Alarm
Model 2401-EC
Pocket-Size Survey Meter
- Gamma Survey
- 3-Range Analog Meter
- Internal Energy-Compensated GM Detector
- Sensitivity (137Cs): 1050 cpm per mR/hr
- Range:
- 0 to 200 mR/hr
- 0 to 210,000 cpm
Model 15
Neutron Dose Survey Meter
- Neutron and Alpha-Beta-Gamma Detection
- 4-Range Analog Meter
- Model 42-14H 3He Proportional Detector
- Sensitivity (241AmBe): 55 cpm per mrem/hr
- Model 44-7 End-Window GM Detector
- Sensitivity (137Cs): 2100 cpm per mR/hr
- Range: 0 to 500,000 cpm
Model 2363 with 42-41L
Neutron Dose Survey Meter
- Neutron and Gamma Detection
- Analog + Digital Scaler-Ratemeter
- External Model 42-41L PRESCILA Detector
- Neutron Sensitivity: 350 cpm per mrem/hr
- Range: 0.1 mrem/hr to 1 rem/hr
- Internal GM Detector
- Gamma Sensitivity: 1000 cpm per mR/hr
- Range: 1 µSv/h to 10 m Sv/h (0.1 mR/hr to 1 R/hr)