Sample Holder for 5.1 cm (2 in.) OD Detectors
- Max Sample Size: 5.1cm (2 in.) dia.
- Features: Compatible with all 5.1 cm (2 in.) OD detectors, including: Model 43-2, Model 43-2-2, Model 44-1, Model 44-2, Model 44-3, Model 44-21, Model 44-98
Request a Quote
Shielded Well Gamma Sample Counter Head
- Detector Type: Gamma NaI(Tl) Integral Line Well Scintillator 4.6 x 5.1 cm (1.8 x 2 in.) [D x L]
- Active Window Area: 1.7 x 3.9 cm (0.66 x 1.6 in.) [D x L]
- Efficiency:
- 125I : 80%
- 99mTc : 90%
- 137C : 33%
- 60Co : 43%
Request a Quote
Shielded Well Gamma Sample Counter Head
- Detector Type: Gamma NaI(Tl) Well Scintillator 5.1 x 4.6 cm (2 x 1.8 in.) [D x L]
- Max. Sample Size: 1.7 x 3.9 cm (0.66 x 1.6 in.) [D x L]
- Efficiency:
- 129I : 65%
- 137Cs : 33%
- 60C0 : 43%
Request a Quote
Beta Sample Counter Head
- Detector Type: Beta Plastic Scintillator
- Max. Sample Size: 12.7 x 0.46 cm (5 x 0.18 in.) [D x L]
- Efficiency:
- 90Sr/90Y : 40%
- 14C : 12%
- 99Tc : 35%
Request a Quote
Shielded Sample Holder with Detector
- Detector Type: Alpha-Beta-Gamma End Window GM
- Max. Sample Size: 5.1 cm (2 in.) dia.
- Efficiency:
- 14C : 2%
- 90Sr/90Y : 10%
- 239Pu : 7%
Request a Quote
Alpha-Beta-Gamma Sample Counter
- Detector Type: Alpha-Beta ZnS(Ag) + Plastic Scintillator
- Max. Sample Size: 5.1 x 1.0 cm (2 x 0.4 in.) [D x L] Adapted for iCam Filters
- Efficiency: 239Pu : 40%
Request a Quote
Windowless Sample Counter Detector
- Detector Type: Alpha-Beta Windowless Gas Flow Proportional
- Max. Sample Size: 5.1 x 0.9 cm (2.0 x 0.4 in.) [D x L]
- Efficiency:
- 3H : 3%
- 14C : 21%
- 63Ni : 36%
- 239Pu : 42%
Request a Quote
Alpha-Beta Sample Counter Head for iCam/Harwell Filters
- Detector Type: Alpha-Beta ZnS(Ag) + Plastic Scintillator
- Max. Sample Size: 5.1 x 1.0 cm (2 x 0.4 in.) [D x L] Adapted for iCam Filters
- Efficiency: 239Pu : 40%
Request a Quote
Alpha-Beta Sample Counter Head for iCam/Harwell Filters
- Detector Type: Alpha ZnS(Ag) Scintillator
- Max. Sample Size: 5.1 x 0.9 cm (2 x 0.4 in.) [D x L]
- Efficiency:
- 239Pu : 37%
- 230Th : 32%
- 238U : 39%
- 14C : 5%
- 99Tc : 27%
- 137Cs : 29%
- 99Sr/90Y : 26%
Request a Quote
Alpha Sample Counter Head
- Alpha-Beta ZnS(Ag) + Plastic Scintillator
- Max. Sample Size: 5.1 x 0.9 cm (2 x 0.4 in.) [D x L]
- Efficiency:
- 239Pu : 37%
- 230Th : 32%
- 238U : 39%
- 14C : 5%
- 99Tc : 27%
- 137Cs : 29%
- 99Sr/90Y : 26%
Request a Quote
Alpha Sample Counter Head
- Detector Type: Alpha ZnS(Ag) Scintillator
- Max. Sample Size: 12.7 x 0.46 cm (5 x 0.18 in.) [D x L]
- Efficiency: 230Th : 37% 239Pu : 37%
Request a Quote
Alpha Sample Counter Head
- Detector Type: Alpha ZnS(Ag) Scintillator
- Max. Sample Size: 5.1 x 0.9 cm (2 x 0.4 in.) [D x L]
- Efficiency: 230Th : 37%
Request a Quote
Alpha Sample Counter Head
- Detector Type: Alpha ZnS(Ag) Scintillator
- Max. Sample Size: 2.5 x 0.15 cm (1 x 0.06 in.) [D x L]
- Efficiency: 230Th : 30%
Request a Quote
Gamma Detector
- Detector Type: Energy-Compensated GM
- Sensitivity (Cs-137):
- 133-2: 1000 cpm per mR/hr
- 133-3: 450 cpm per mR/hr
- 133-4: 100 cpm per mR/hr
- 133-6: 18 cpm per mR/hr
- 133-7: 4.2 cpm per mR/hr
- Linear Range
- 133-2: 0.1 to 200 mR/hr
- 133-3: 0.1 mR/hr to 1 R/hr
- 133-4: 1 mR/hr to 2 R/hr
- 133-6: 4 mR/hr to 6 R/hr
- 133-7: 25 mR/hr to 30 R/hr
Request a Quote
Waterproof Gamma Scintillator Detector
- Description:
- 5.1 x 5.1 cm (2 x 2 in.) NaI(Tl) Scintillator Stainless Steel Housing Hard-Wired 3 m (10 ft.) Cable
- Submersible up to 30 m (100 ft)
- Part Number: 47-2427